INSTRUCTIONS
Process Black
White
White/Black MOTION PRO, INC. LOGO
Motion Pro, Inc.
867 American Street
San, Carlos, CA 94070
Tel: 650.594.9600 Fax: 650.594.9610
www.motionpro.com
Instructions for Motion Pro 08-0468 Digital Tire Pressure Gauge
I08-0468 7/2010
BLEED VALVE
Operation
1. Press “ON/OFF” button. LCD will display “0.0” and the current
pressure unit (PSI, BAR, KG/CM², kPa).
2. Place chuck fi rmly onto tire valve, ensuring no air leakage.
3. Read the exact value.
4. To reduce tire pressure, press bleed valve and the new
value will be displayed.
5. Press the “ON/OFF” button for 1 second to turn gauge off
(gauge will turn off automatically after 3 minutes).
Important: Do not use gauge of pressures above 100 psi.
Doing so may damage gauge and void warranty.
Zero Reset:
To reset zero at ambient pressure, press the “ON/OFF” button
for 5 Seconds until 0.0 is displayed.
Change pressure unit:
To change unit, press and hold the “LIGHT” button (right) until
pressure unit icon changes, then release the button. Repeat
procedure until desired unit icon is displayed on LCD
(PSI, BAR, KG/CM², kPa).
Replace Battery
NOTE: The battery needs to be replaced when the battery
icon appears on the display.
1. Pull back the anti-shock cover.
2. Remove the top body setscrew with a small Phillips type screwdriver
and carefully remove the battery cover.
3. Remove old battery and insert new battery (uses one 9-volt battery).
4. Reassemble battery cover to body and reinstall screw and tighten.
Specifi cations:
Pressure Range : 0.0 to 60.0 psi
Accuracy : 1% F.S. at 25ºC (77ºF)
Resolution : 0.1 psi
Battery : 9V Alkaline
Battery Service Life : 1000 tests
Auto Off : 180 sec.
Operating Temp. : -10 to 50ºC (14 to 122ºF)